    심냉 공기분리공정의 공기압축공정에서 전력비 절감을 위한 액화천연가스 냉열 활용에 대한 연구
  • Title(Eng)
    A Study on the Utilization of the LNG Cold Heat for the Reduction of the Power Consumption in Main Air Compressors in Cryogenic Air Separation
  • Keyword
    Air separation unit(공기분리공정), Compressor(압축기), Cryogenic distillation column(심냉 증류탑), LNG(액화천연가스), Cold heat(냉열)
  • Author(Kor)
    조두희⋅조정호†
  • Author(Eng)
    DUHEE CHO, JUNGHO CHO†
  • Date
    2020-06
  • Attach file
  • Page
    Page. 333~327
  • Abstract(Eng)
  • In this work, a study for the reduction of the electric power consumption has been estimated in main air compressors in the air separation unit through cryogenic distillation columns with PRO/II with PROVISION V10.2 at AVEVA company. Both required LNG mass flow rate and cold heat contained in 1 ton of LNG were also predicted using Peng-Robinson equation of state with Twu’s new alpha function. Through this work, we concluded that 32.33―48.69% of electric power could be saved by using LNG cold heat.